| Brand Name: | HAIDA |
| MOQ: | 1 |
HD-E918 Bypass Diode Thermal Test Machine is primarily used to detect the protective performance and heat generation of bypass diodes in photovoltaic modules under hotspot effects.
| Item | Specification |
|---|---|
| Pulse Power Supply | 20μs~999s (adjustable) |
| Current Range | 0-60A; Deviation ±2% |
| Voltage Range | 0-5V; Deviation ±2% |
| DC Power Supply Current Range | 0-60A; Deviation ±1% |
| DC Power Supply Voltage Range | 0-20V; Deviation ±1% |
| Temperature Acquisition Channel Accuracy | ≤1℃ |
| Voltage Acquisition Accuracy | ≤0.2V |
| Functional Test | Diode I-V curve <1s |
| Thermal Runaway Test | Forward current → Reverse voltage ≤10ms |
| Power | Single phase, 220V, 50Hz |
| Item | Specification |
|---|---|
| Internal Dimension | 400×400×400mm (W×D×H) |
| External Dimension | 760×690×1720mm (W×D×H) |
| Temperature Range | RT~200℃ |
| Temperature Display Accuracy | 0.1℃ |
| Temperature Stability | ±1.0℃ |
| Temperature Uniformity | ±2℃ |
| Temperature Rise Time | 5℃/min in average |
| Controller | Touch screen control |
| Inner Chamber Material | Stainless steel plate |
| External Chamber Material | Cold rolled steel plate baking varnish treatment |
| Observation Window | 250×250mm |
| Lighting Device | Internal lighting for easy sample observation |
| Box Door | Single door left open with explosion-proof chain |
| Test Holes | 2 test holes (50mm diameter) for temperature, voltage, current collection lines |
| Insulation Material | High efficiency compressed glass wool |
| Safety Devices | Over-temperature alarm, pressure relief port (200×200mm) |
| Air Circulation System | Convection air circulation system |
| Weight | Approx. 170kg |
| Power | Single phase 220V, 50Hz |