Product Details:
Payment & Shipping Terms:
|
Interior Size: | 350×400×350(W×H×D) | Power: | Electronic |
---|---|---|---|
Product Name: | Environmental Testing Chambers | Material: | SUS# Stainless Steel Plate |
Cooling Method: | Water | Output Mode: | P.I.D. + S.S.R. System Coordinates With Channel Control |
Highlight: | environmental testing equipment,environmental testing machine |
Multi Function Control Environmental Test Chambers Temperature Shock Test For Metal / Plastic
1. Description:
Temperature Shock Tester is used to test the bearing extent of the material structures and composite material in an instant and continuous high temperature and extremely low temperature environment , that is in the shortest time to test its thermal expansion and contraction caused by chemical change or physical harm. Application objects, including metal, plastic, rubber, electronics ... and other materials can be used as a basis to improve their products or reference.
Application Industry:
1. Electronic products: mobile phones, computers, television, video recorders and so on
2. Textile fabric products: clothes, hats, shoes, ropes
3. Wire and cable: data cable, usb,
4. Leather products: handbags, wallets, leather shoes, leather chairs
5. Instrumentation, vehicles, plastic products, metal,
6. Food, chemical, building materials, medical, aerospace
7. Others...
Test Standard:GJB150.5A-2009,GB/T 2424.13-2002/IEC 60068-2-33:1971,GB/T 2423.1-2008/IEC6008-2-1-2007
2. Specification:
Model |
HD-E703-50K40 | HD-E703-50K55 | ||
Nominal content product(L) | 50 | |||
Interior dimension(mm) | 350×400×350(W×H×D) | |||
Overall dimension(mm) | 1230×1500×1830(W×H×D) | |||
Technical parameters | Temperature range |
High temperature | RT~170 ℃ | |
Low temperature | -75℃ ~RT | |||
Test area | -40℃ ~150℃ | -50℃ ~150℃ | ||
Temperature shock range | High temperature | 60℃ ~150℃ | ||
Low temperature | -10℃ ~-40℃ | -10℃ ~-50℃ | ||
Normal temperature area | Room temperature | |||
Temperature and humidity deviation | ±0.3℃,±2%R·H | |||
Average difference in temperature and humidity | ±2℃,±3%R·H | |||
Heating rate | 2℃/min | |||
Cooling rate | 0.5~1.2℃/min | |||
Storage time | RT→-75℃≤ 65min | |||
Heat storage time | RT→170℃≤ 35min | |||
Refrigeration system | Compressor | Import of France taikang/Germany | ||
Cooling way | Water cooling or air cooling | |||
Condenser | Stainless steel brazed plate type heat exchanger | |||
Heater/evaporator | Nickel-chromium electric heater/finned evaporator | |||
Microcomputer & display screen | TT-5188T3-7HL Taitong controller | |||
Circulation fan | Axial flow fan | |||
Safety measures | No fuse switch, compressor overpressure, overheat, overcurrent protection, fuse, water flow protection, phase sequence protection, oil pressure protection, pressure relief protection, low pressure protection, pressure cylinder protection, temperature limit protection | |||
Material | Chassis shell | High quality cold rolled steel sheet is sprayed with static electricity | ||
Inner wall of the case | SUS304# Stainless steel plate | |||
Heat preservation material | Polyurethane rigid foam + high density fiberglass cotton | |||
Standard configuration | Test hole, floodlight, double vacuum bulletproof glass observation window | |||
Power supply | three-phase,380V,50Hz | |||
3. Features:
Refrigeration system:
1. The refrigerating unit adopts French taikang compressor, and USES American dupont environmental refrigerant (R404a), and adopts dual cryogenic circuit system design, which is convenient to use different compressors for work in different temperature domains, so as to increase the equipment.
2. The temperature and humidity control adopts P.I.D. + S.S.R system to coordinate with the channel, with the function of automatic calculation, which can immediately correct the temperature and humidity changing conditions, making the temperature and humidity control more accurate and stable.
3. Imported controller is adopted for temperature and humidity. The relative temperature and humidity performance is set and displayed accurately, and the resolution reaches 0.1℃
Control system:
1. Adopt imported LCD programmable temperature controller or imported temperature and humidity control instrument and temperature and humidity control table;
2. Intelligent digital display PID microcomputer temperature control instrument;
3. The temperature is controlled by means of thermal balance.
Chamber view:
Contact Person: Mary