Product Details:
Payment & Shipping Terms:
|
Brine Tank Capacity: | 15L;25L;40L | Equipment Material: | P.V.C Rigid Plastic Board |
---|---|---|---|
Lab Volume: | 108L; 270L;600L | Power: | Electronic |
Product Name: | Cyclic Corrosion Test Chamber | Temperature Precision: | ±1℃ |
Temperature Range: | 35℃~55℃ | Use: | Paint;electroplating;organic And Inorganic Coating;anode Processing;antirust Oil And So On |
High Light: | corrosion testing equipment,salt spray testing equipment |
Corrosion - Resistant Salt Spray Corrosion Test Chamber For Paint Electroplating
1. Product introduction:
Corrosion - Resistant Salt Spray Corrosion Test Chamber is is designed for surface treatment of corrosion-resistant capacity test for various materials,including paint, electroplating, organic and inorganic film, antirust oil,chemicaltreatment, and then achieves a long period of resistance to corrosion products.
Ferrous and non-ferrous metals are attacked continuously by humidity, acids, solutions, gases etc. It is therefore vitally important to choose the correct surface protection. There are many materials and qualities on the market and their properties must be properly assessed. Materials intended to prevent corrosion must be tested if failures are to be avoided. Furthermore the comparative quality control during production is of increasing importance. The best known processes employ spray vapour tests using various salt solutions as well as condensation water climates.
Corrosion - Resistant Salt Spray Corrosion Test Chamber For Paint , Electroplating
3. Design standard:
CNS:3627,3385,4159,7669,8886;JIS:D0201,H8502,H8610,K5400,Z2371;
ISO: 3768,3769,3770;
ASTM: B117,B268.
Model |
HD-E808-60A |
HD-E808-90A |
HD-E808-120A |
Inner box size: |
60×40×45 |
90×60×50 |
120×100×50 |
Outside box size: |
107×60×118 |
141×88×128 |
190×130×140 |
Equipment material: |
Both internal and external material is using imported P.V.C rigid plastic board; the case cover is using transparent rigid plastic board P.V.C. |
||
Temperature range: |
35℃~55℃ |
||
Temperature fluctuations: |
≤±0.5℃ |
||
Temperature uniformity: |
≤±2℃ |
||
Temperature precision: |
±1℃ |
||
Test chamber temperature |
NSS ACSS 35±1℃ CASS:50±1℃ |
||
Saturated air barrel temperature: |
NSS ACSS 47±1℃ CASS 63±1℃ |
||
Brine temperature: |
35℃±1℃ |
||
Spray quantity: |
1.0~2.0 ml / 80cm2 / hr |
||
PH: |
NSS ACSS6.5~7.2 CASS 3.0~3.2 |
||
Lab volume: |
108L |
270L |
600L |
Brine tank capacity: |
15L |
25L |
40L |
Power: |
1∮AC220V,10A |
1∮AC220V,15A |
AC 1∮,220V,30A |
Multiple safety protection devices: |
Water shortage/ over temperature / phase protection |
||
Standard accessories: |
Test salt, measure bucket, tool etc 1 set |
Picture Show :
(salt spray chamber)Related products: | |
Model / Link | Interior Dimensions(W x D x H) |
HD-E808-60 | 600x400x450mm) |
HD-E808-90 | 900x600x500mm |
HD-E808-120 | 1200x1000x500mm |