Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Services
Home ProductsEnvironmental Test Chambers

HPLC Gas Chromatography Mass Spectrometry Analysis Machine High Performance

Good quality Environmental Test Chambers for sales
Good quality Environmental Test Chambers for sales
The instruments you recommend are very suitable for the testing needs of our laboratory products, after-sale is very patient to answer all our questions, and guide us how to operate, very nice.

—— Div Harish

You are very professional partners and we are willing to establish long-term cooperative relations with you.

—— Wojtek Krawczyk

On behalf of the company to visit your factories and companies, the technical staff is very professional and patient, I think I would be happy to cooperate with you again.

—— Manuel Munoz

I'm Online Chat Now

HPLC Gas Chromatography Mass Spectrometry Analysis Machine High Performance

China HPLC Gas Chromatography Mass Spectrometry Analysis Machine High Performance supplier
HPLC Gas Chromatography Mass Spectrometry Analysis Machine High Performance supplier HPLC Gas Chromatography Mass Spectrometry Analysis Machine High Performance supplier HPLC Gas Chromatography Mass Spectrometry Analysis Machine High Performance supplier HPLC Gas Chromatography Mass Spectrometry Analysis Machine High Performance supplier HPLC Gas Chromatography Mass Spectrometry Analysis Machine High Performance supplier

Large Image :  HPLC Gas Chromatography Mass Spectrometry Analysis Machine High Performance

Product Details:

Brand Name: HD
Model Number: HD-GC5890N

Payment & Shipping Terms:

Minimum Order Quantity: 1
Packaging Details: Each set protected with resin fiber and PP film, then put into Strong wooden case with operation manual and video inside.
Delivery Time: 15
Contact Now
Detailed Product Description
Temperature Range: Room Temperature Is 5 ~ 450 ℃ Maximum Heating Rate: 120℃/ Min
Temperature Programmed: 7 FID Maximum Operating Temperature: 400℃
TCD The Sensitivity: ≥10000mv.ml/mg [n-C16] FPD Detection Limit: ≤2x10-13 Gs(P),≤5x10-11g/s(S)

Hplc gas chromatography mass spectrometry analysis machine price

 

Instrument introduction

Optional multiple detector and filling column, shunt/unshunt capillary column injection system;Fully compatible with agilent 6890N gas chromatograph detector and related detector control board, chromatographic workstation and automatic sampler.Excellent performance, excellent performance, stable and reliable operation.

 

Application field

Petroleum, chemical industry, food, pharmaceutical, environmental protection, disease control, safety supervision, water, electricity, metallurgy, scientific research institute, quality inspection department.

 

Supporting products

Headspace injector, gas generator, gas purifier, thermal analyzer, pyrolyzer, etc.

 

Performance characteristics

1. New integrated digital electronic circuit, high control precision, stable and reliable performance, can reach the temperature control precision of 0.01 ℃.

2. Mixer has boot self-diagnosis function, stopwatch function convenient traffic (stable), timer function operation, power storage protection function, and key lock function, anti power mutation function, network data communication and remote control function.

3. The unique design of the sample system can lower the detection limit.

4. It can be used to select automatic/manual gas six-way injection valve sampler, headspace injector, thermo-analytical sampler, pyrolysis furnace sampler, methane converter, automatic sampler.

5. It is faster to control and stabilize the temperature of the furnace.

6. It can be installed with FID, TCD, FPD, NFD and PDHID detectors. All kinds of detectors can be independently controlled. The hydrogen flame detector can be easily disassembled and installed to facilitate cleaning or changing the nozzle.The stable time of thermal conductivity cell detector (TCD) is less than 20min.

7. It has automatic on-line detection function.

HPLC Gas Chromatography Mass Spectrometry Analysis Machine High Performance

Technical indicators

Column temperature box
The chamber size 28×30×18cm
Temperature range Room temperature is 5 ~ 450 ℃
Temperature setting 1 ℃;Programmed heating rate 0.1 ℃
Maximum heating rate 120℃/ min
Temperature stability When the environmental temperature change 1 ℃, 0.01 ℃
Temperature programmed Seventh order heating
Operation column loss compensation (dual channel)
Inlets
S/SL (split/splitless) injector,On-column inlet,PTV injector,gas source inlet or gas switching valve,P/T (Purge-and-Trap) system,solid phase microextraction
Flame Ionization detector (FID)
Maximum operating temperature 400℃
Detection limit ≤5×10-12g/s [n-C16]
Drift ≤5×10-13A/30min
The noise ≤2×10-13A
Dynamic linear range ≥107
Thermal Conductivity detector (TCD)
Maximum operating temperature 400℃
The sensitivity ≥10000mv.ml/mg [n-C16]
Drift ≤100μV/30min
The noise ≤2×10-13A
Dynamic linear range ≥104
Flame photometric detector (FPD)
Maximum operating temperature 250℃
Detection limit ≤2x10-13 gs(P),≤5x10-11g/s(S)
Dynamic linear range ≥103(P),≥102(S)
The noise ≤2×10-12A
Drift ≤4x10-11A/30min
Electron capture detector (ECD)
Maximum operating temperature 350℃
Detection limit ≤1x10-14g/ml(y-666)
Dynamic linear range ≥104
The noise ≤20μA
Drift ≤50μV/30min
Nitrogen–phosphorus detector (NPD)
Maximum operating temperature 400℃
Detection limit ≤5x10-13 gs(P),≤1x10-12g/s(N)
Dynamic linear range ≥103(P),≥103(N)
The noise ≤4×10-13A
Drift ≤2.5x10-12A/30min
Photoionization detector (PDHID)
Detection limit ≤5ppb
Optional configuration
The control software Automatic sampler B6891N.

 